Research Playbook

Project playbook 05 · CHART or TRIPOD-LLM

AI or LLM evaluation playbook

Rigor beats novelty in a crowded field

Studies that test how well a large language model (LLM) such as ChatGPT, Gemini or Claude answers orthopaedic questions are quick to run and easy to place, which is exactly why there are so many. “We asked a chatbot 20 questions and two surgeons graded them” is no longer enough to interest an editor.

The studies that still get published define a real task, fix the prompts in advance, compare the model with a meaningful standard, use blinded graders with a rubric, and report the exact model version and date. Results go stale as models update, so the method, not the score, is what lasts.

Evaluate the model like a diagnostic test, not a demo.

Pre-specify the questions, the reference standard, the grading rubric and the analysis. Then run the model the same way every time and report everything someone would need to repeat it.

You leave with: A LLM evaluation protocol2–4 months to submission
Learn the framework

The core framework

Four decisions that make an LLM study publishable.

Make them before the first prompt. Changing them after seeing outputs is the AI-study version of p-hacking.

STEP 01

Pick a task that matters

Who would act on the model’s output?

Choose a realistic use: patients asking about surgery, trainees studying, clinicians drafting notes, researchers searching literature. Then ask whether your angle is new. Safety failures, harder or more realistic questions, comparisons with clinicians, and how answers change across versions are less crowded than accuracy on FAQs.

STEP 02

Fix the prompts and the runs

Could someone else reproduce your outputs?

Write the exact prompts in advance and publish them. Record the model, version, access route (app or API), date and any settings. Start a fresh session for each prompt, and run each one more than once, because the same prompt can give different answers.

STEP 03

Choose a reference standard

Compared with what?

Grade against something defensible: clinical guidelines, an expert-written answer key, a trusted patient resource such as OrthoInfo, or published systematic reviews. A comparison with human experts answering the same questions makes results far easier to interpret.

STEP 04

Grade blind, with a rubric

Would two graders agree?

Use at least two graders who do not know which source wrote each answer, a written rubric with anchored levels (for example accuracy, completeness and potential for harm), and report inter-rater agreement. Without this, scores mostly reflect the graders.

Study types

Common LLM study designs in orthopaedics.

Each answers a different question and has its own main weakness.

DesignQuestionReference standardMain weakness
Patient-question answersAre answers to patient questions accurate, complete and readable?Guidelines, OrthoInfo, expert answers; readability formulasCrowded; small question sets; graders who know the source
Exam or knowledge questionsHow does the model score on board-style questions?The answer key; resident score reportsQuestions may be in training data; exam questions are often copyrighted, so check permissions
Reference and literature tasksCan the model find or cite real evidence?PubMed; published systematic reviewsNeeds a strict, pre-defined test for a fabricated reference
Clinical vignettesDoes the model reach the right diagnosis or plan?Expert panel or guidelineVignettes are cleaner than real patients; real cases need IRB and privacy safeguards
Image interpretationCan a model read radiographs or photos?Radiologist or surgeon readsImage rights and de-identification; performance varies by image type

Make it last

Results go stale. Design for that.

A model can be updated or retired before your paper is published. These choices keep the study useful anyway.

Record version and date

Name the model and version exactly, how you accessed it and the dates of every run. “ChatGPT” alone is not a method.

Compare several models

Testing more than one model, or one model over time, tells readers something that outlives any single version.

Publish your materials

Share prompts, the rubric and raw outputs in a supplement so others can rerun the study on newer models.

Move fast

Plan for 2–4 months from idea to submission. Run all prompts in a short window so the model does not change mid-study.

No patient data in consumer chatbots, and check what you are allowed to upload.

Never enter identifiable patient information into a public AI tool; use synthetic vignettes or an institution-approved system with IRB oversight. Copyrighted exam questions, journal content and some datasets have terms that may forbid uploading them. Read the terms first.

Week by week

From idea to submission in about three months.

The plan’s estimate for an AI evaluation is 2–4 months. Most of the time goes into building the question set and grading, not running the model.

  1. Weeks 1–2

    Task, novelty and protocol

    • Pick the task and the users it affects
    • Search PubMed for the model, topic and “large language model” to see what is published
    • Write the protocol: question source, models, prompts, reference standard, rubric, analysis
    • Check your target journal’s AI policy and the terms of any material you will use
  2. Weeks 3–4

    Build the question set and rubric

    • Collect questions from a defensible source (patient FAQs, guideline topics, expert-written items)
    • Write the reference answers or key
    • Write an anchored rubric; pilot it on a few answers with two graders and refine
    • Ask your IRB whether a determination is needed (surveys of patients or trainees usually need review)
  3. Week 5

    Run the models

    • Fresh session per prompt; same settings throughout
    • Repeat each prompt (often three times) to measure consistency
    • Save every output with model, version and timestamp
    • Strip source labels so graders are blinded
  4. Weeks 6–8

    Grade and analyze

    • Graders score independently with the rubric
    • Calculate agreement (for example ICC or kappa) and resolve disagreements by a set rule
    • Compare against the reference standard and any human comparator
    • Pre-specified statistics; report effect sizes, not just p-values
  5. Weeks 9–12

    Write and submit

    • Write to CHART or TRIPOD-LLM (checklist below)
    • Supplement: prompts, rubric, outputs
    • Disclose how AI was used in writing the paper, per the journal
    • Submit quickly, before the tested version is retired

Reporting

What an LLM evaluation must report.

Two reporting guidelines are designed for LLM studies. CHART covers studies of chatbot health advice; TRIPOD-LLM covers broader LLM research. These are the items reviewers check most; use the official checklist that fits your study.

Your progress through the checklist0/14
The model
Inputs
Evaluation
Results and ethics

Learn from published studies

Three LLM evaluations, three lessons in method.

All are free to read. Look at how each defines its reference standard and its scoring before reporting any results.

Journal of Medical Internet Research · 2024

Hallucination Rates and Reference Accuracy of ChatGPT and Bard for Systematic Reviews: Comparative Analysis

Chelli M, Descamps J, Lavoué V, et al.

Published rotator cuff systematic reviews served as the gold standard, and a reference counted as hallucinated if two of title, first author or year were wrong. A strict, pre-defined test.

JAAOS Global Research & Reviews · 2025

Evaluating if ChatGPT Can Answer Common Patient Questions Compared With OrthoInfo Regarding Rotator Cuff Tears

Jurayj A, Nerys-Figueroa J, Espinal E, et al.

A real comparator: the same questions answered by OrthoInfo. Five surgeons rated accuracy and appropriateness, and readability was measured with the Flesch-Kincaid grade level.

Journal of Experimental Orthopaedics · 2025

ChatGPT Provides High-Quality Answers to FAQs About High Tibial Osteotomy Despite Low Inter-Rater Agreement

Akcaalan S, Şahbat Y, Loddo G, Erden T, Kocaoglu B

Four surgeons rated the same answers twice. Agreement between surgeons was low, which the authors report openly: a reminder that grader agreement is a result, not a formality.

Common pitfalls

What stalls projects at this step.

Each of these costs weeks or credibility. Most are easy to avoid once you can name them.

A crowded question

“ChatGPT answers FAQs about X” has been done for most procedures. Find a new task, comparator or safety angle.

Unreported version and date

Without them, nobody can interpret or repeat your results.

One run per prompt

The same prompt can give different answers. Repeat runs and report consistency.

Graders who know the source

Unblinded grading inflates or deflates scores. Strip labels before grading.

No reference standard

A score of 4.5 out of 5 means little without a comparison with experts or a trusted resource.

Patient data or copyrighted material uploaded

This can breach privacy law or licensing terms. Use synthetic cases and permitted content.

Your deliverable

Your LLM evaluation protocol

Write this before you open the model. Publish the prompts and rubric with the paper.

Template
LLM EVALUATION PROTOCOL

TASK
Use case and who would rely on the output:
What is new compared with published studies:
Target journal and its AI policy (checked on):

MODELS
Model(s), exact version(s):
Access route (app / API) and settings (temperature, system prompt):
Planned run dates:

INPUTS
Question source and selection criteria:
Number of questions (and why):
Exact prompt wording (attach full list):
Fresh session per prompt: yes
Repeat runs per prompt:
Permissions checked for copyrighted or licensed material:
Patient data used: none / synthetic vignettes / IRB-approved system only

REFERENCE STANDARD
Guideline / expert key / OrthoInfo / systematic review / human comparator:

GRADING
Rubric domains and anchored levels (e.g., accuracy 1-5, completeness 1-3, potential harm yes/no):
Graders (number, expertise):
Blinding method:
Agreement statistic (ICC / kappa) and disagreement rule:

ANALYSIS
Primary outcome:
Comparisons and tests:
Consistency across runs:
Readability measure (if patient-facing):

ETHICS
IRB determination:
AI-use disclosure for the manuscript:

Before you move on

0/7
Get BroBot feedback on it

Capstone exercise

Review your LLM study with BroBot

Paste your protocol or Methods section. BroBot checks it against the items reviewers look at first in LLM evaluations: reproducibility, reference standard, blinded grading, agreement and ethics.

BroBot checks for

  • Task and novelty
  • Model reporting
  • Pre-specified prompts
  • Sessions and repeat runs
  • Reference standard
  • Grading rubric
  • Blinding and agreement
  • Analysis
  • Ethics, privacy and permissions
  • Version limitations

BroBot research reviews are currently unavailable. You can still use the lesson and its template.

Never paste patient identifiers. BroBot gives educational feedback, not IRB, legal or statistical sign-off. Check journal and institutional rules at the source.